title: "Certifications | Guangzhou Great Power Energy and Technology Co., Ltd."
description: "Cumple con UL 1973, IEC 62619, NFPA 855 y normas GB. Registro global de cero accidentes de seguridad. Verifique nuestras credenciales para sus necesidades de importación."
url: "/es/certifications"
language: "es"
alternates:
  - { language: "en", url: "/certifications" }
  - { language: "ru", url: "/ru/certifications" }
---

Cumplimiento y normas

# Normas internacionales

Great Power cells and systems are tested against the standards that govern global energy storage. Below is a summary of the primary international certifications held by our products, with links to the corresponding certificate records.

| Norma | Alcance | Certificado |
| --- | --- | --- |
| UL 1973 | Norma de seguridad para sistemas estacionarios de almacenamiento de energía en aplicaciones conectadas a la red, gestión de carga y estaciones de carga de VE. | Certificado |
| UL 9540A | Metodología de pruebas de incendio a gran escala que evalúa la propagación del escape térmico a nivel de celda, módulo, unidad e instalación. | Certificado |
| IEC 62619 | Requisitos de seguridad para celdas y baterías secundarias de litio utilizadas en aplicaciones industriales. | Certificado |
| IEC 61000 | Límites de compatibilidad electromagnética y métodos de medición para inmunidad y emisiones. | Certificado |
| UN38.3 | Protocolo de prueba de seguridad de transporte de las Naciones Unidas para celdas y baterías de ion-litio. | Certificado |
| CE | Marcado de conformidad europeo que cubre la Directiva de Baja Tensión y las directivas CEM. | Certificado |
| RoHS | Restricción de sustancias peligrosas en equipos eléctricos y electrónicos. | Certificado |

Nota:Specific certificate numbers and validity dates are available upon request or via the detailed records linked above.

[Solicitar copias originales](/es/contact)[Ver todos los certificados](/es/certifications)

## Normas chinas

Compliance with national and military-grade specifications for domestic deployment and export.

Great Power's energy storage systems meet the mandatory Chinese national standards (GB) and industry-specific regulations governing lithium-ion battery safety, performance, and quality management. These certifications ensure interoperability with local grid infrastructure and adherence to strict fire safety protocols.

### Normas nacionales (GB)

Requisitos técnicos obligatorios para la seguridad y el rendimiento de baterías en China.

- GB
- GBT36276-2018
- GB36276:2023
- GBT36276-2023
- GB (Certification in progress)
- GB/T36276

### Normas sectoriales

Cumplimiento específico para aplicaciones automotrices e industriales.

- QCT-743-2006

### Normas militares

Sistemas de gestión de calidad para adquisiciones relacionadas con la defensa.

- GJB9001B

### Certificación de calidad

Marcas de certificación voluntaria de productos para generar confianza en el consumidor.

- CQC

Las copias originales de los certificados están disponibles bajo solicitud para fines de diligencia debida y auditoría.

[Solicitar documentos](/es/contact)

## Sistemas de gestión

Quality, environmental, occupational health and safety, and automotive-grade process certifications governing our manufacturing operations.

### ISO 9001

Verified

### ISO 45001:2018

Verified

### ISO 14001

Verified

### IATF 16949

Verified

Original certificate copies available upon request for due diligence.

## Seguridad y protección contra incendios

Energy storage systems are evaluated not only for performance but for their behavior under fault conditions. Great Power designs to recognized fire-protection and ingress-protection standards so that cells, cabinets, containers and integrated systems can be deployed in populated and industrial environments with documented safety margins.

### Cumplimiento NFPA 855

The National Fire Protection Association standard NFPA 855 governs the installation of stationary energy storage systems, covering siting, separation distances, ventilation, detection and suppression requirements. Our containerized and cabinet-based ESS architectures are dimensioned against these provisions, including compartmentalization, thermal-runaway propagation limits and emergency-response access, so integrators can reference a compliant baseline when preparing permitting packages.

### Tecnología de supresión por aerosol

Each enclosure is provisioned for aerosol-based active suppression. Aerosol generators deliver fine potassium-carbonate particles that interrupt combustion chemistry at the cell level, extinguishing lithium-ion fires without water damage or residual liquid. The system operates on multi-stage detection—temperature, voltage deviation and gas sensing—and triggers locally within the affected module while isolating adjacent compartments to limit propagation.

### Clasificaciones de protección contra ingreso

Outdoor cabinets and containers are rated IP55 as standard, providing dust-protected operation and resistance to low-pressure water jets from any direction. Selected configurations reach IP67, sustaining temporary immersion and heavy condensation typical of coastal, mining and telecom sites. Ratings are verified through third-party testing and recorded per product family.

IP55

Protección contra polvo · Chorros de agua

IP67

Estanco al polvo · Inmersión temporal

IP65

Estanco al polvo · Chorros a baja presión

IP44

Sólidos >1mm · Salpicaduras de agua

### Normas de seguridad aplicables

[Ver todas las certificaciones](/es/certifications)

- UL9540A
- UL 9540A
- NFPA 855

Registros de certificación disponibles bajo solicitud. Copias originales emitidas por organismos acreditados.

[Solicitar copias originales de certificados](/es/contact)

## Solicitud de verificación

For procurement due diligence, we provide original certificate copies and test reports. Submit your requirements below and our compliance team will respond within one business day.

### What you will receive

#### Original scans

High-resolution PDFs of the requested certificates with issuing body seals and validity dates visible.

#### Test reports

Resúmenes de laboratorios de terceros (UL, TÜV, SGS) que cubren fuga térmica, EMC y seguridad en transporte cuando sea aplicable.

#### Scope statements

Management-system certificates accompanied by their audit scope so you can confirm coverage of the relevant product line.

Tiempo de respuesta típico: menos de 24 horas en días hábiles.