Great Power cells and systems are tested against the standards that govern global energy storage. Below is a summary of the primary international certifications held by our products, with links to the corresponding certificate records.
| Norma | Alcance | Certificado |
|---|---|---|
| UL 1973 | Norma de seguridad para sistemas estacionarios de almacenamiento de energía en aplicaciones conectadas a la red, gestión de carga y estaciones de carga de VE. | Certificado |
| UL 9540A | Metodología de pruebas de incendio a gran escala que evalúa la propagación del escape térmico a nivel de celda, módulo, unidad e instalación. | Certificado |
| IEC 62619 | Requisitos de seguridad para celdas y baterías secundarias de litio utilizadas en aplicaciones industriales. | Certificado |
| IEC 61000 | Límites de compatibilidad electromagnética y métodos de medición para inmunidad y emisiones. | Certificado |
| UN38.3 | Protocolo de prueba de seguridad de transporte de las Naciones Unidas para celdas y baterías de ion-litio. | Certificado |
| CE | Marcado de conformidad europeo que cubre la Directiva de Baja Tensión y las directivas CEM. | Certificado |
| RoHS | Restricción de sustancias peligrosas en equipos eléctricos y electrónicos. | Certificado |
Nota:Specific certificate numbers and validity dates are available upon request or via the detailed records linked above.
Normas chinas
Compliance with national and military-grade specifications for domestic deployment and export.
Great Power's energy storage systems meet the mandatory Chinese national standards (GB) and industry-specific regulations governing lithium-ion battery safety, performance, and quality management. These certifications ensure interoperability with local grid infrastructure and adherence to strict fire safety protocols.
Normas nacionales (GB)
Requisitos técnicos obligatorios para la seguridad y el rendimiento de baterías en China.
- GB
- GBT36276-2018
- GB36276:2023
- GBT36276-2023
- GB (Certification in progress)
- GB/T36276
Normas sectoriales
Cumplimiento específico para aplicaciones automotrices e industriales.
- QCT-743-2006
Normas militares
Sistemas de gestión de calidad para adquisiciones relacionadas con la defensa.
- GJB9001B
Certificación de calidad
Marcas de certificación voluntaria de productos para generar confianza en el consumidor.
- CQC
Sistemas de gestión
Quality, environmental, occupational health and safety, and automotive-grade process certifications governing our manufacturing operations.
ISO 45001:2018
ISO 14001
IATF 16949
Seguridad y protección contra incendios
Energy storage systems are evaluated not only for performance but for their behavior under fault conditions. Great Power designs to recognized fire-protection and ingress-protection standards so that cells, cabinets, containers and integrated systems can be deployed in populated and industrial environments with documented safety margins.
Cumplimiento NFPA 855
The National Fire Protection Association standard NFPA 855 governs the installation of stationary energy storage systems, covering siting, separation distances, ventilation, detection and suppression requirements. Our containerized and cabinet-based ESS architectures are dimensioned against these provisions, including compartmentalization, thermal-runaway propagation limits and emergency-response access, so integrators can reference a compliant baseline when preparing permitting packages.
Tecnología de supresión por aerosol
Each enclosure is provisioned for aerosol-based active suppression. Aerosol generators deliver fine potassium-carbonate particles that interrupt combustion chemistry at the cell level, extinguishing lithium-ion fires without water damage or residual liquid. The system operates on multi-stage detection—temperature, voltage deviation and gas sensing—and triggers locally within the affected module while isolating adjacent compartments to limit propagation.
Clasificaciones de protección contra ingreso
Outdoor cabinets and containers are rated IP55 as standard, providing dust-protected operation and resistance to low-pressure water jets from any direction. Selected configurations reach IP67, sustaining temporary immersion and heavy condensation typical of coastal, mining and telecom sites. Ratings are verified through third-party testing and recorded per product family.
IP55
Protección contra polvo · Chorros de agua
IP67
Estanco al polvo · Inmersión temporal
IP65
Estanco al polvo · Chorros a baja presión
IP44
Sólidos >1mm · Salpicaduras de agua
Normas de seguridad aplicables
Ver todas las certificaciones- UL9540A
- UL 9540A
- NFPA 855
Solicitud de verificación
For procurement due diligence, we provide original certificate copies and test reports. Submit your requirements below and our compliance team will respond within one business day.
What you will receive
Original scans
High-resolution PDFs of the requested certificates with issuing body seals and validity dates visible.
Test reports
Resúmenes de laboratorios de terceros (UL, TÜV, SGS) que cubren fuga térmica, EMC y seguridad en transporte cuando sea aplicable.
Scope statements
Management-system certificates accompanied by their audit scope so you can confirm coverage of the relevant product line.
Tiempo de respuesta típico: menos de 24 horas en días hábiles.